OMNISCANNER User Guide
4 - 2
Set Reference
Connect OMNISCANNER and OMNIREMOTE through
their test connector ports using the Link Adapter
and the Channel Adapter. Select Set Reference
to display the SET REFERENCE screen.
OMNISCANNER will immediately start to communi-
cate with OMNIREMOTE.
While the reference data is being established, a
gauge indicates the progress.
OMNISCANNER notifies you when the process has been completed. The
REMOTE INFO screen will be displayed.
Note
Set Reference is needed to periodically verify and establish the signal
reference for attenuation.
Press ESC to return to the SETUP screen.
Set Reference with the OMNIFIBER Adapters
Note
The fiber reference expires each day at midnight. It must be set each
calendar day that OMNIFIBER adapters are used. The reference value
should also be set every time the test configuration changes.
A reference value must be established before a
loss measurement can be calculated.
With the OMNIFIBER adapters attached to
OMNISCANNER and OMNIREMOTE, and the launch
cable(s) (jumper(s)) in place, select Set Reference
to display the CONNECT JUMPERS screen.
Connect the jumpers as displayed and press
to continue.
The SET REFERENCE screen will be displayed
while the reference data is being established.
OMNISCANNER notifies you when the process has
been completed and the FIBER INFO screen will
be displayed.