2 - 11
OMNISCANNER User Guide
Typical Test Configurations for Twisted Pair Cabling
Link
The graphic shows the connection
of OMNISCANNER to a Modular 8
Jack in the wiring closet, and
OMNIREMOTE to a Modular 8 jack
in the work area.
Use the supplied LINK ADAPTERS
at both ends of the link to attach
OMNISCANNER and OMNIREMOTE to
the Modular 8 jacks.
During permanent link Autotests,
the effects of the link adapters
are removed from the measure-
ments.
The permanent link method
measures the link only, from jack to jack (including the Modular 8 plug
that plugs into the Jack).
Link with Punch Down Block and Modular 8 Jack
The graphic shows the connection
of OMNISCANNER to an IDC (110)
block in the wiring closet, and
OMNIREMOTE to a Modular 8 jack in
the work area.
The Punch Down Block Adapter
kits 110 A LINK ADAPTER and
110 B LINK ADAPTER are avail-
able (as optional accessories) to
interface the OMNISCANNER and
OMNIREMOTE with IDC (110) punch-
down blocks.
Use the 110 A or B LINK
ADAPTER to attach OMNISCANNER
to the 110 Punch Down block. At
the other end of the link, use the
CAT 6
PERMANENT
LINK
ADAPTER
CAT 6
PERMANENT
LINK
ADAPTER
Punch
Down
Block
110 A
LINK
ADAPTER