OMNISCANNER User Guide
5 - 12
Press (Graph) to display the PSNEXT graph
for the currently highlighted pair. PSNEXT is
displayed for the frequency indicated by the
cursor position.
Press (Pairs) to view PSNEXT graphs for
other pairs.
Press ESC to exit the POWER SUM NEXT screen.
Power Sum ELFEXT
Power Sum ELFEXT is calculated from the summation of the indi-
vidual ELFEXT effects on each pair by the other three pairs.
In the POWER SUM ELFEXT screen, the worst case
margin for all near and far pairs is shown at the
top of the screen.
The pairs are displayed in the column on the left
side, followed by the PSELFEXT in decibels (dB),
the margin/limit, and the frequency. The result
for each pair is tagged with a PASS , Marginal
PASS , Marginal FAIL , or FAIL indicator.
Press or to toggle between the PSELFEXT results for
OMNISCANNER and OMNI-Remote.
Press (Graph) to display the PSELFEXT graph
for the currently highlighted pair. PSELFEXT is
displayed for the frequency indicated by the
cursor position.
Press (Pairs) to view PSELFEXT graphs for
other pairs.
Press ESC to exit the POWER SUM ELFEXT screen.