4 - 7
OMNISCANNER User Guide
(Ohms) from the predefined list.
To setup whether or not the cable is shielded, use the ê to highlight
Shield: and press ENTER. Use the é or ê arrow key to make the
appropriate selection. If ‘Yes’ is selected, the wiring for the shield will
be measured during the Autotest and used to determine if the
Wiremap will PASS or FAIL.
With a or fiber optic cable highlighted,
press (Edit) to edit an existing custom
cable, or press (New) to create a new fiber
based on the GRI values of the highlighted cable.
Cable Name and GRI @ 1300 (multimode) or 1310
(single-mode) can be viewed and changed.
Note
Default fibers cannot be edited.
A fiber cable’s Graded Refractive Index (GRI) differs depending on the
supplier. To receive accurate length results, OMNISCANNER allows you to
define the GRI values for both wavelengths.
To change the fiber’s mode, use the é or ê arrow key to highlight the
mode. Press Enter to select Multimode 62.2 mm, Multimode 50
mm or Single-mode.
Press (Save) to save the edited cable into the Custom Cable
folder.
Press ESC to return to the CABLES screen.
Projects
Select Projects to display the PROJECTS screen. It
contains a list of all projects that are currently
stored in OMNISCANNER. Predefined default projects
are: TIA, ISO/IEC, VENDOR, OMNI, IEEE, ATM, AS/
NZ, ANSI. OMNISCANNERs project feature allows you
to organize test specifications, cables types, and
test results into Projects.