3 - 7
OMNISCANNER User Guide
2. Remove the middle launch cable and the connector sleeves that were
attached to the middle launch cable.
3. Connect the OMNIFIBER MAIN to one end of the duplex link under test
and the OMNIFIBER REMOTE to the opposite end.
4. Press .
Loopback Autotest using OMNIFIBER MAIN
This configuration is used to test single fibers, reels and short cables
when both ends of the fiber under test are accessible from the same
location.
Note
The loopback Autotest assumes that the 2-Jumper Method was used
to make the reference measurement.
To run a Loopback Autotest proceed as follows:
1. Do not disconnect the
black launch cable, which
is attached to the TX port
of the OMNIFIBER (it is
circled in the graphic).
2. Do not disconnect the
coupler from the black
launch cable (it is circled in
the graphic).
3. Disconnect the white launch cable from the RX port of the
OMNIFIBER and the connector sleeve. Leave the two white connectors
dangling.
4. Attach the cable to be tested to the RX port on the OMNIFIBER and
the connector sleeve.
5. Press .
2 m Launch Cable
Fixed Connection Fixed Connection
Cable under Test