OMNISCANNER User Guide
4 - 4
Wiremap, Length, Delay and Skew limits are also
displayed. The Wiremap numbers show the pairs
that are being tested.
The second page shows limits for Resistance,
NEXT, Attenuation, and Return Loss.
The third page lists limits for ELFEXT, ACR, and
Power Sum NEXT measurements.
The fourth page shows limits for Power Sum
ELFEXT and Power Sum ACR. This screen also
informs you whether or not OMNIREMOTE is
required to perform the selected Autotest.
Test that are performed during an Autotest are
clearly marked . Tests that are not required
when performing an Autotest have no icon.
Disabled tests may or may not show limits in the
description field. An precedes the test name
for tests being performed during the Autotest,
but the results are not used to determine PASS or
FAIL.
Defined test limits will be displayed right below
the test name. If a test has no limit, the limit
description field will be empty.
For fiber optic cabling the View Autotest
Detail screen shows the standard being used in
the titlebar.
The test that are performed during an Autotest
are clearly marked .
If an precedes the test name, the test will be
performed for information purpose only; the
results are not used to determine PASS or FAIL.
The required reference method Jumper,
Jumpers, or Jumpers is displayed in the View
Autotest Detail screen together with the test
limits. Use the function key to view the
limits for 50 mm fibers. When running an