The Name: field is initially empty. Press ENTER to edit the name. The
first and last Circuit ID fields contain the default Circuit ID from the
Project that was highlighted when the (New) key was pressed.
Note
New and edited project names are placed at the bottom of the list in
the PROJECTS screen. OMNISCANNER can store up to 16 projects.
Editing a Circuit ID
To edit or create a Circuit ID, highlight an item in the PROJECTS screen
and press (New) or (Edit).
Use the ê to highlight the First Circuit ID: field and press ENTER.
The Circuit ID consists of 16 characters, which allows the sophisticated
construction of Circuit IDs. Each character can be incremented.
The example shows how to quickly create an incremental Circuit ID.
Enter MT-F01 (MyTest - Floor 01) -PP01 (- Patch Panel 01) -P01 (-
Position 01) in the First Circuit ID: field.
Press ENTER to terminate the edit mode.
Use the ê to highlight the Last Circuit ID: field and press ENTER.
Enter MT-F12 (MyTest - Floor 12) -PP02 (- Patch Panel 02)
-P48 (- Position 48) in the Last Circuit ID: field. Press ENTER to termi-
nate the edit mode.
The Circuit IDs will increment from right to left. The positions will
change first from 01 to 48. Next the Patch Panels will increase from 01
to 02. Last the floors will increase from 01 to 12.
Press (List) to review the continuous list of Circuit IDs that was
just created.