PostBase One Franking System
160
On the dynamic scale (back cover) Remove the connection cable of the
sealer / feeder: Unscrew and carefully pull
off the plug.
Pull out power cable.
On the sealer (back cover) Remove the power supply unit.
Remove the connection cable of the
feeder: Unscrew and carefully pull off the
plug.
On the feeder (back cover) Pull out power cable.
Remove FSCP plug (termination plug):
Unscrew and carefully pull off the FSCP
plug.
Separate the components of the franking system
Slightly lift the franking machine and move
it to the right.
Slightly lift the dynamic scale and move it
to the right.
Slightly lift the sealer and move it to the
right.
Franking machine
Housing
connector