EasyManua.ls Logo

Funkwerk R1202 - Page 240

Funkwerk R1202
594 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 88: Networking->Access Rules->Interface Assignment->New
The Networking->Access Rules->Interface Assignment->New menu consists of the fol-
lowing fields:
Fields in the Basic Parameters menu
Field Description
Interface Select the interface for which a configured rule chain is to be as-
signed.
Access Rules Select a rule chain.
Silent Deny
Define whether the sender is to be informed if an IP packet is
denied.
The function is enabled with #/.
The function is activated by default.
Reporting Method
Define whether a syslog message is to be generated if a packet
is denied.
Possible values:
* ,: No syslog message.
 (default value): A syslog message is generated with the
protocol number, source IP address and source port number.
1,: A syslog message is generated with the contents of the
first 64 bytes of the denied packet.
14 Networking Funkwerk Enterprise Communications GmbH
226 bintec Rxxx2/RTxxx2

Table of Contents