Field Value
Contact Enter the relevant contact person. Here you can enter the e-
mail address of the system administrator, for example.
A character string of up to 255 characters is possible.
The default value is 53*9:;9.
Maximum Number of
Syslog Entries
Enter the maximum number of syslog messages that are stored
internally in the device.
Possible values are to .
The default value is . You can display the stored messages in
Monitoring->Internal Log.
Maximum Message
Level of Syslog Entries
Select the priority of system messages above which a log
should be created.
System messages are only recorded internally if they have a
higher or identical priority to that indicated, i.e. all messages
generated are recorded at syslog level 1#$.
Possible values:
$%): Only messages with emergency priority are re-
corded.
0/: Messages with emergency and alert priority are recor-
ded.
4%/: Messages with emergency, alert and critical prior-
ity are recorded.
: Messages with emergency, alert, critical and error pri-
ority are recorded.
:$: Messages with emergency, alert, critical, error and
warning priority are recorded.
*%: Messages with emergency, alert, critical, error,
warning and notice priority are recorded.
 (default value): Messages with emergency,
alert, critical, error, warning, notice and information priority are
recorded.
1#$: All messages are recorded.