10. MAINTENANCE AND TROUBLESHOOTING
10-10
10.8 Troubleshooting
If you suspect equipment trouble, first follow the troubleshooting information in the ta-
ble below. If normal operation cannot be restored, do not attempt to check inside any
unit. Contact a FURUNO agent or dealer for assistance.
Symptom Cause, checkpoint Remedy
The power cannot be
turned on.
Check that the power cable is
firmly connected to the power
input at the rear of the Commu-
nication Unit.
Check that the power for the
FELCOM is on at the ship’s
switchboard.
Check for blown fuse in the
power cable.
Reconnect the power cable if it
has loosened.
Turn on the power at the ship’s
switchboard.
Referring to section 10.6, re-
place the fuse.
No communications.
• Cannot receive EGC
messages.
• Cannot receive polling
command.
• Cannot receive e-mail.
Do the PV test. The [Overall
Result] should be [Pass].
Referring to section 2.5, con-
firm the following items.
- C/N value is “OK”.
- You are logged in.
If the PV test result is [Fail], fol-
low the information in
subsection 10.3.3.
Check for interfering objects
near the antenna. If interfering
objects are present, relocate
the antenna, referring to the in-
stallation manual.
Error message is dis-
played.
Refer to the Alert List in Appendix
7.

Table of Contents