APPX. 6 DIGITAL INTERFACE
AP-34
*1 The transfer of responsibility is allowed.
ALR: Alarm sentence
ARC: Alert command refused
3009 Caution B 2 Lost ALARM
UNIT
Check the IC-306 connection.
3009 Caution B 3 Lost SSAS
UNIT
Check the IC-307 connection.
3009 Caution B 0 Lost ext unit Not used
3016 Caution B 1 Lost position GPS error. Contact to FURUNO
Service
3016 Caution B 2 Lost position Check the position-fixing equip-
ment.
3016 Caution B 0 Lost position Not used
3079 Caution B Not used PRINTER ER-
ROR
Check the printer and paper
supply.
630003 Caution B Not used BBER OVER BBER over 80%. Select NCS
manually.
630010 Caution B Not used INVALID MES
ID
Contact to FURUNO Service.
630050 Caution B Not used EEPROM ER-
ROR
Contact to FURUNO Service.
630643 Caution B Not used DISTRESS
BUTTON
Contact to FURUNO Service.
630200 Caution B Not used 1ST LOCAL
UNLOCK
Contact to FURUNO Service.
630201 Caution B Not used 2ND LOCAL
UNLOCK
Contact to FURUNO Service.
Alert ID Priority Category Instance First Text Second Text
$**ALR,Hhmmss.ss,xxx,A,A,c—c*hh<CR><LF>
1 2 3 4 5
1. Time of alarm condition change, UTC (000000.00 to 240001.00)
2. Unique alarm number (identifier) at alarm source (000 to 999)
3. Alarm condition (A=threshold exceeded, V=not exceeded)
4. Alarm acknowledge state (A=acknowledged, V=not acknowledged)
5. Alarm description text (alphanumeric)
$**ARC,hhmmss.ss,aaa,x.x,x.x,c*hh<CR><LF>
1 2 3 4 5
1. Release time (000000 - 2355959.99)
2. Manufacturer mnemonic code (FEC, NULL)
3. Alert identifier (001-999999)
4. Alert instance (NULL)
5. Refused Alert Command (A, Q, O, S)
A=acknowledge
Q=request/repeat information
O=responsibility transfer
S=silence