2.0 — 187 — 12 October 2012
After the flight
Clearing the site
21.3.3 Disassemble the launcher
P
REREQUISITES
● Crank
Once the flight is done, you can disassemble the launcher.
1 Fix the crank between your ties.
2 Release the force with the crank very gently while pulling the release handles upwards.
Make sure you counteract the force on the elastics. It might be possible that you have to
tighten the elastics a little bit so that you are able to pull the release handles upwards.
C
AUTION: It is recommended that a second person connects the crank to the tightening
system so the forces can be released gently.