GE PANDA Specifications

General IconGeneral
TypeInfant Warmer
ManufacturerGE Healthcare
Control ModesManual, Servo
Integrated ScaleYes
SpO2 MonitoringOptional
Bed TiltYes
Heater TypeCeramic
AlarmsPower Failure
Power Requirements100-240 VAC, 50/60 Hz
ModelPANDA
Resuscitation OptionsOptional
Skin Temperature Probe Accuracy±0.3°C

Summary

Important Safety Information

Warnings, Cautions, and Notes

Details critical safety warnings, cautions, and notes for operating and servicing the equipment.

Chapter 1: Functional Description

1.1.1 Mechanical Controls and Cable Connections

Details the physical components, ports, and connectors on the warmer unit.

1.1.2 Controls and Displays

Explains the function of various buttons, knobs, and display elements on the control panel.

1.3 System Functions

Explains the operational capabilities and functions of the warmer system.

Chapter 2: Installation, Maintenance, and Checkout

2.1 Warmer Maintenance Schedule

Outlines recommended maintenance intervals for operator and service tasks.

2.2 Installation and Service Checkout Procedures

Provides step-by-step instructions for initial installation and pre-operational checkout.

Chapter 3: Calibration

3.1 Scale Calibration (Bedded Models Only)

Explains the procedure for calibrating the bed's integrated scale.

Chapter 4: Troubleshooting

4.1 Service Mode

Instructions on how to access and navigate the service mode for diagnostics and settings.

4.1.7 Diagnostics

Details various diagnostic tests for system components and software.

4.2 PC Command Line Interface

Using a PC for advanced diagnostics, software updates, and commands.

4.2.1 Accessing the PC Command Line Interface

Steps for connecting a PC and accessing the command line interface.

Chapter 5: Repair Procedures

5.1 Common Hand Tools

Lists essential hand tools required for performing repair procedures.

5.3 Heater Housing Repairs

Procedures for repairing various components within the heater housing.

5.4 Electronic Enclosure Repairs

Steps for disassembling and repairing components within the electronic enclosure.

5.5 Probe Panel Housing Repairs

Procedures for disassembling and repairing the probe panel housing.

5.7 Lower Unit Repairs (Bedded and Freestanding Models)

Procedures for repairing components in the lower unit of bedded and freestanding models.

Appendix A: Specifications

A.6 SpO2 Specifications

Details the performance specifications and standards for the SpO2 option.

Appendix B: Electromagnetic Compatibility

B.1 Electromagnetic Compatibility (EMC) Guidance

General guidelines and safety standards for EMC compliance.

Appendix C: Alarm Priorities

Appendix D: Troubleshooting

D.1 Service Mode (Application Software 1.0.9 and Earlier)

Accessing and navigating the service mode for diagnostics and configuration.

D.1.4 Diagnostics Using Serial Port

Utilizing a PC for advanced diagnostics and software updates via serial port.

Appendix E: Installing Wall Mount Units

E.1 Pre-Installation Preparation

Steps for preparing the wall structure for mounting the warmer bracket.

E.2 Wall Mount Bracket Installation

Instructions for securely mounting the wall bracket to the wall.

E.4 Heater Head Installation and Heater Alignment

Steps for installing the heater head and ensuring correct alignment for optimal performance.