Appendix B: Electromagnetic Compatibility
Manufacturer’s Guidance and Declaration Regarding Electromagnetic Immunity
B-2 Service Manual
B.3 Manufacturer’s Guidance and Declaration Regarding Electromagnetic
Immunity
The Giraffe/Panda Warmer is intended for use in the electronic environment specified below. The user of the
Giraffe/Panda Warmer should ensure that it is used in such an environment.
Note: Ut is the main voltage before application of the test level.
Electromagnetic Immunity
Immunity Test IEC 60601 Test
Level
Compliance Level Electromagnetic Environment
Guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
± 6kV contact
± 8kV air
± 6kV contact
± 8kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material the relative humidity
should be at least 30%.
Connectors marked with ESD symbol
excluded.
Electrical fast
transient/burst
IEC 61000-4-4
± 2kV for power
supply line.
± 1kV for input/
output line.
± 2kV for power supply
line.
± 1kV for input/output
line.
Mains power quality should be that of a
typical commercial or hospital
environment.
Surge
IEC 61000-4-5
± 1kV differential
Mode.
± 2kV common
mode line.
± 1kV differential Mode.
± 2kV common mode
line.
Mains power quality should be that of a
typical commercial or hospital
environment.
Voltage dips,
short
interruptions and
voltage
variations on
power supply
input lines
IEC 61000-4-11
< 5 % Ut (> 95 %
dip in Ut) for
0.5 cycle
40 % Ut (60 %
dip in Ut) for
5cycles
70% Ut (30 % dip
in Ut) for 25
cycles
<5% Ut (>95%
dip in Ut) for
5sec.
< 5 % Ut (> 95 % dip in
Ut) for 0.5 cycle
40 % Ut (60 % dip in Ut)
for 5 cycles
70 % Ut (30 % dip in Ut)
for 25 cycles
< 5 % Ut (> 95 % dip in
Ut) for 5 sec.
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of the Giraffe/
Panda Warmer requ continued
operation during power mains
interruptions, it is recommended that the
Giraffe/Panda Warmer be powered from
an uninterruptible power supply or a
battery.
Power frequency
(50/60 Hz)
magnetic field
environment
IEC 61000-4-8
3 A/m 3 A/m Power frequency magnetic fields should
be at levels characteristic of a typical
location in a typical commercial or
hospital.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PANDA and is the answer not in the manual?

GE PANDA Specifications

General IconGeneral
TypeInfant Warmer
ManufacturerGE Healthcare
Control ModesManual, Servo
Integrated ScaleYes
SpO2 MonitoringOptional
Bed TiltYes
Heater TypeCeramic
AlarmsPower Failure
Power Requirements100-240 VAC, 50/60 Hz
ModelPANDA
Resuscitation OptionsOptional
Skin Temperature Probe Accuracy±0.3°C