Chapter 1: Functional Description
Introduction
1-2 Service Manual
The information in this manual refers to all models, unless otherwise specified. The term “bedded” refers to
both the Giraffe Warmer and the Panda iRes Warmer.
The Giraffe model is intended for use in a neonatal intensive care unit. It features a mattress which can be
rotated as needed by the operator to gain better access to the patient. Also included are general
observation lights and a procedure light.
The procedure light is mounted on a ball joint so that it can be directed where needed on the bed surface.
The Panda models are intended for use in a labor and delivery unit. They also include the same general
observation lights as the Giraffe Warmer, but the procedure light is optional.
All Giraffe and Panda units feature the same heater head to house the radiant heater. Due to the small size
of the heater reflector and its compound elliptical shape, designed specifically for this product, the heater
head is very compact compared with other warmers currently on the market. This compact size limits the
area the heater head occupies over the bed surface. By leaving the area over the bed clear, the caregiver
can observe and treat the patient unobstructed. Additionally, this open area allows the head of an X-ray
machine to be placed over the patient without moving the heater head or patient.
All Giraffe and Panda units also feature optional integrated SpO
2
and Resuscitation Modules. The SpO
2
option allows the caregiver to monitor the patient’s blood oxygen level, while the optional Resuscitation
Module allows the caregiver to administer forced breathing if required. The Resuscitation Module may
feature either a traditional bag and mask technology or a T-piece technology.
TABLE 1-2. Warmer Splash Screen Images
Panda iRes Warmer Splash Screen Panda Freestanding and Panda
Wall Mount Warmer non-bedded
Splash Screen
Giraffe Warmer Splash Screen

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PANDA and is the answer not in the manual?

GE PANDA Specifications

General IconGeneral
TypeInfant Warmer
ManufacturerGE Healthcare
Control ModesManual, Servo
Integrated ScaleYes
SpO2 MonitoringOptional
Bed TiltYes
Heater TypeCeramic
AlarmsPower Failure
Power Requirements100-240 VAC, 50/60 Hz
ModelPANDA
Resuscitation OptionsOptional
Skin Temperature Probe Accuracy±0.3°C