GSE Scale Systems - 45
Chapter 4 Parameter Setup (Advanced) Technical Reference Manual
PARAMETER # SELECTION DESCRIPTION
SECTION - 4.6
P5110.2 Betwn Output active if weight is
between target values.
P5110.3 Outsd Output active if weight is not
between target values.
P5110.4 Tare Output active if < TARE > key
is executed.
P5110.5 Zero Output active if < ZERO >key
executed
P5110.6 Acc Output active if ACC operation
occurs
P5110.7 Mot'n Output active if motion occurs.
P5110.8 NotMt Output active if motion ceases.
P5110.9 alwys Any de-activation is
momentary.
P5110.º never Output will not become active
on its own. An activate
command within a Macro or an
RS-232 message is
necessary to activate this
setpoint.
P5111.0 Hold * 0.0 No extra delays.
P5111.1 0.1 1/10 second minimum
activation time.
P5111.2 0.2 2/10 second minimum
activation time.
P5111.3 0.3 3/10 second minimum
activation time.
P5111.º 25.0 25.0 second minimum
activation time.
P5112.0 Macro 0 Macro 0 will execute when
setpoint activates.
P5112.1 Macro 1 Macro 1 will execute when
setpoint activates.
P5112.2 Macro 2 Macro 2 will execute when
setpoint activates.
P5112.3 Macro 3 Macro 3 will execute when
setpoint activates.
P5112.4 Macro 4 Macro 4 will execute when
setpoint activates.
P5112.5Macro 5 Macro 5 will execute when
setpoint activates.
P5112.6Macro 6 Macro 6 will execute when
setpoint activates.
P5112.7Macro 7 Macro 7 will execute when
setpoint activates.