Model 574 Programmable Counting System (PCS)
54 - GSE Scale Systems
PARAMETER # AUTO-CONFIGURATION DESCRIPTION
P60001. E2Avl * 1666 Displays amount of
available E
2
memory.
P60002. RAMsz * 8K Displays amount of
installed RAM.
P60003. RAMdy * 3989 Displays amount of
dynamically allocated
RAM.
P60004. RAMav * 3610 Displays amount of
available RAM.
P60005. #Rows * 0 Shows number of
stored data rows.
P60010 dbRAM * 0 (0 w/no Option) Database Memory
P60011 dbAve * 0 Available RAM
P60012 dbUse * 0 In Use Ram
P60013 BlkSz * 0 Contiguous RAM
available
P60014 dbase Error * none Database results check
P60021 - P60036 Databases #1 - #16
P60100. 1993 *GSE* Displays copyright
assertion.
P60101. 0574- 01003 Displays software
revision code.
P60102. Apr 23 1994 Displays date code of
the software.
P60200. B SN XXXXX Displays Main PC
Board serial number.
P60201. AudTr XXXXX Displays Audit Trail
number.
P60202. I SN1 XXXXX Displays Instrument
serial number.
P61100. Crrnt mV/V Displays an
approximation of the
current mv/V output of
connected load cell or
platform.
Parameters 61101 thru 61121 are all transferable parameters associated with the unique A/D converter on the main
board. Refer to Chapter 29 for information about Swapping the A/D to another unit.
P61101. CAL Factr Displays fine calibration
factor. This parameter is for
a single point calibration.
This parameter is not
accessable if P119 is enabled
(Multi-point Linearization).