<186>Oct 13 16:48:08 2011 H3C 10IFNET/2/210231a64jx073000020: log_type=port;content=Line
protocol on the interface Vlan-interface1 is DOWN.
NOTE:
• The closing set of angel brackets (< >), the space, the forward slash (/), and the colon are all required
in the above format.
• The format in the previous section is the original format of system information, so you may see the
information in a different format. The displayed format depends on the log resolution tools you use.
Following is a detailed explanation of the fields involved in system information:
PRI (priority)
Priority is calculated using the following formula: facility*8+severity. In the formula, facility represents the
logging facility name, which can be configured when you set the log host parameters. Facility ranges
from local0 to local7 (16 to 23 in decimal integers) and defaults to local7. Facility marks different log
sources on the log host, and to query and filter the logs of the corresponding log source. Severity ranges
from 0 to 7. Table 1 details the v
alue and meaning associated with each severity.
Note that the priority field takes effect only when the information has been sent to the log host.
timestamp
Times tamp records the time when the system information was generated. The time stamp of the system
information sent to the log host has a precision of seconds, and that to all the other destinations has a
precision of milliseconds. The time stamp format of the system information sent to the log host is
configured with the info-center timestamp loghost command, and that of the system information sent to
the other destinations is configured with the info-center timestamp command.
Table 4 Description on the time stamp parameters
Time stamp
parameter
Description Example
boot
System up time (that is, the duration for this
operation of the device), in the format of
xxxxxx.yyyyyy, where xxxxxx represents the
higher 32 bits, and yyyyyy represents the
lower 32 bits.
System information sent to all destinations
except log host supports this parameter.
%0.109391473 Sysname
FTPD/5/FTPD_LOGIN: User ftp
(192.168.1.23) has logged in
successfully.
0.109391473 is a time stamp in the boot
format.
date
Current date and time of the system, in the
format of Mmm dd hh:mm:ss:sss yyyy.
System information sent to all destinations
supports this parameter.
%May 30 05:36:29:579 2011 Sysname
FTPD/5/FTPD_LOGIN: User ftp
(192.168.1.23) has logged in
successfully.
May 30 05:36:29:579 2011 is a time
stamp in the date format.
iso
Time stamp format stipulated in ISO 8601
Only the system information sent to a log host
supports this parameter.
<189>2011-05-30T06:42:44 Sysname
%%10FTPD/5/FTPD_LOGIN(l): User ftp
(192.168.1.23) has logged in
successfully.
2011-05-30T06:42:44 is a time stamp in
the iso format.

Table of Contents

Other manuals for H3C S3100V2-52TP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100V2-52TP and is the answer not in the manual?

H3C S3100V2-52TP Specifications

General IconGeneral
BrandH3C
ModelS3100V2-52TP
CategorySwitch
LanguageEnglish

Related product manuals