39
Time stamp
parameter
Description Example
none
No time stamp is included.
System information sent to all destinations
supports this parameter.
% Sysname FTPD/5/FTPD_LOGIN: User
ftp (192.168.1.23) has logged in
successfully.
No time stamp is included.
no-year-date
Current date and time of the system, with year
information excluded.
Only the system information sent to a log host
supports this parameter.
<189>May 30 06:44:22 Sysname
%%10FTPD/5/FTPD_LOGIN(l): User ftp
(192.168.1.23) has logged in
successfully.
May 30 06:44:22 is a time stamp in the
no-year-date format.
Sysname (host name or host IP address)
• If the system information is sent to a log host in the format of UNICOM, and the info-center loghost
source command is configured, the field is displayed as the IP address of the device that generates
the system information.
• In other cases (when the system information is sent to a log host in the format of H3C, or sent to
other destinations), the field is displayed as the name of the device that generates the system
information, namely, the system name of the device. You can use the sysname command to modify
the system name. For more information, see Fundamentals Command Reference.
%% (vendor ID)
This field indicates that the information is generated by an H3C device. It is displayed only when the
system information is sent to a log host in the format of H3C.
vv
This field is a version identifier of syslog, with a value of 10. It is displayed only when the output
destination is log host.
module
The module field represents the name of the module that generates system information. You can enter the
info-center source ? command in system view to view the module list.
level (severity)
System information is divided into eight levels based on its severity, from 0 to 7. See Table 1 for definitions
and descriptions of these severity levels. The levels of system information generated by modules are
predefined by developers, and you cannot change the system information levels. However, with the
info-center source command, you can configure to output information of the specified level and not to
output information lower than the specified level.
digest
The digest field is a string of up to 32 characters, outlining the system information.
For system information destined to the log host:
• If the character string ends with (l), the information is log information
• If the character string ends with (t), the information is trap information
• If the character string ends with (d), the information is debugging information
For system information destined to other destinations:

Table of Contents

Other manuals for H3C S3100V2-52TP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100V2-52TP and is the answer not in the manual?

H3C S3100V2-52TP Specifications

General IconGeneral
BrandH3C
ModelS3100V2-52TP
CategorySwitch
LanguageEnglish

Related product manuals