Ripple-2 Node specifications
Item Specification
Port-to-Port Isolation 50 dB
Nominal Return Input
Level
8 dBmV per 6.4 MHz channel (nominal); configurable
US MER 37 dB (typical)
Agency certifications
• CB:
◦ IEC 62368-1
Viewing the laser output with optical instruments, such as a magnifier or microscope, within a
distance of 100 millimeters (four inches) may pose an eye hazard.
Follow these precautions:
• Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure
• Never look at an optical fiber using a direct magnification fiber scope without verifying that all light
wave sources on the fiber are turned off
• Never look directly into an optical connector
• Install protective covers or caps over connectors when they are not being used
• Always assume that opposed optical connectors and cables are energized
◦ Always verify that a fiber is not energized by making an optical power measurement of the fiber or
connector before cleaning or before visual inspection
29 Installation Guide