Upgrading Pebble-2 module software
Parameter Description
rpd-vcvs-addr [CC:SS] = Virtual slot
For example: admin@CableOS> show rpn 1:0 verbose
Tamper Sensor: Closed
Temperature: 36.0C/96.8F
Non-volatile Database: Valid
GENERAL
PS NO. AC INPUT (VAC) +5 (VDC) DC SELECT (VDC) +24/34 VDC TEMPERATURE
------ -------------- -------- --------------- ---------- -----------
0 72.0 +5.0 +1 +34.0 46.0C/115F
ELECTROLYTIC ELECTROLYTIC
CAPACITOR 1 TEMP CAPACITOR 2 TEMP
---------------- ----------------
48.0C/118F 49.0C/120F
The parameter values have already been described above under the lid and power commands.
Upgrading Pebble-2 module software
Pebble-2 module software is upgraded remotely from the CableOS Core server using CLI.
This procedure assumes that the Pebble-2 module is online and can communicate with the CableOS
Core server.
If the Pebble-2 is not online and if, for any reason, you must perform the upgrade, contact Harmonic
technical support.
Before you begin
The device that stores the Pebble-2 module software prior to software installation must be reachable over
the IP network from the Pebble-2 module.
The device that stores the Pebble-2 module software prior to software installation must support HTTP (80
port only), SCP or FTP protocols.
1. Run this command to display available Pebble-2 modules and to verify that it/they are online :
admin@CableOS> show cable rpd
Example:
Pebble-2 information is displayed, as shown in this example:
VC:VS MAC-ADDRESS IP-ADDRESS SW-VERSION STATUS
----- -------------- ------------------- ------------------ -----------
1:10 0020.a324.14d7 192.168.8.112 6.0.20.2-1+auto29 online
2. Download the software image, from the location provided by your Harmonic representative, to any
device in your network that can be reached over the IP network from the Pebble-2 module.
67 Installation Guide