8.5 Message List
114
Temperature Correction
:CALCulate:TCORrect:STATe
1, 0, ON or OFF Set Temperature Correction execution
127
:CALCulate:TCORrect:STATe?
(ON or OFF)
Queries the Temperature Correction
execution setting
127
:CALCulate:TCORrect:PARameter
<Reference Temp.>,
<Temp. Coefficient>
Sets the Temperature Correction
constant
127
:CALCulate:TCORrect:PARameter?
(<Reference Temp.>,
<Temp. Coefficient>)
Queries the Temperature Correction
constant setting
127
Temperature Conversion (∆t)
:CALCulate:TCONversion:DELTa:STATe
1, 0, ON or OFF Set Temperature Conversion execution
128
:CALCulate:TCONversion:DELTa:STATe?
(ON or OFF)
Queries the Temperature Conversion
execution setting
128
:CALCulate:TCONversion:DELTa:PARa
meter
<Initial Resistance>,<Ini-
tial Temp.>,<Constant>
Sets the Temperature Conversion
constant
128
:CALCulate:TCONversion:DELTa:PARa
meter?
(<Initial Resistance>,
<Initial Temp.>,<Con-
stant>)
Queries the Temperature Conversion
constant setting
128
Averaging Function
:CALCulate:AVERage
2 to 100 Sets the no. of samples to average
129
:CALCulate:AVERage?
(2 to 100)
Queries the no. of samples to average
setting
129
:CALCulate:AVERage:STATe
1, 0, ON or OFF Sets Averaging function execution
128
:CALCulate:AVERage:STATe?
(ON or OFF)
Queries the Averaging function execution
setting
128
Statistical Functions
:CALCulate:STATistics:STATe
1, 0, ON or OFF
Sets Statistical Calculation function
execution
129
:CALCulate:STATistics:STATe?
(ON or OFF)
Queries the Statistical Calculation
function execution setting
129
:CALCulate:STATistics:CLEAr
Clears Statistical Calculation results
129
:CALCulate:STATistics:NUMBer?
(<Total data count>,
<Valid data count>)
Queries the data count
129
:CALCulate:STATistics:MEAN?
(<Mean>) Queries the mean value
129
:CALCulate:STATistics:MAXimum?
(<Maximum value>,
<Data no.>)
Queries the maximum value
129
:CALCulate:STATistics:MINimum?
(<Minimum value>,
<Data no.>)
Queries the minimum value
130
:CALCulate:STATistics:LIMit?
(<Hi count>,<IN count>,
<Lo count>, <Measure-
ment fault count>)
Queries comparator results
130
:CALCulate:STATistics:BIN?
(<BIN0 count>,...,<BIN
9 count>,<OUT count>,
<Measurement fault
count>)
Queries BIN results
130
:CALCulate:STATistics:DEViation?
(<σn>,<σn-1>) Queries standard deviation
130
:CALCulate:STATistics:CP?
(<Cp>,<Cpk>) Queries the Process Capability Indices
130
Comparator
:CALCulate:LIMit:STATe
1, 0, ON or OFF Sets comparator execution
131
:CALCulate:LIMit:STATe?
(ON or OFF) Queries the comparator execution setting
131
:CALCulate:LIMit:BEEPer
OFF, HI or IN Sets the beep sound
131
Message ([ ] = optional)
Data Contents
( ) = response data
Description
Ref
page