Figure 4-53 Power off procedure of failed management module
(B) Press and hold the Power switch for four seconds or more
This procedure forces the management module to power off.
1. Ensure that Power LED lights in green.
2. Press and hold the Shutdown switch until Power LED turns to light in
amber.
3. Release the Shutdown switch.
Figure 4-54 Power LED and Shutdown switch
Power off the switch module
Use the following procedure to power down the switch module.
(A) Use a Web console
This procedure initiates a remote power off for the failed switch module.
1. Ensure that Power LED lights on green.
2. Logon to the Web console and select Resource.
3. Select Modules > All Modules > Switch modules > the failed
module.
4. Select Condition tab.
5. Click Power OFF.
6. Ensure that the shutdown was completed and Power LED lights in amber.
4-62
Common process for replacement
Hitachi Compute Blade 500 Series System Service Manual