End of "Restoring iSCSI settings".
Go to
Restoring FCoE settings on page 7-95.
Restoring the UMC and Personality settings
This procedure shall be performed when the server model is neither CB 520H
B2/B3/B4 nor CB 520X B1/B2/B3, the firmware version of management
module is A0180 or later, and the firmware version of server blade is as
follows.
Server model Firmware version
CB 520H A1/B1 01-70 or later
CB 520A A1 02-38 or later
CB 540A A1/B1 03-20 or later
1. Click Power and select Power On in Remote console menu.
2. Power Control dialog box is displayed. Click Yes.
The target server blade is powered on.
3. Wait about five minutes until System Configuration and Boot
management window is displayed.
4. Press Esc in System Configuration and Boot Management window.
When the Do you want to exit … dialog box is displayed, press Y.
7-90
Configuring Emulex mezzanine card
Hitachi Compute Blade 500 Series System Service Manual