2. The flash drive in the expansion blade may not be indicated when the
data consistency check is in progress on the drive.
When the flash drive is not indicated, wait ten minutes, return to the
CBTP main menu, select Reboot, and then press Enter.
Restart CBTP, and then repeat from step 1.
3. The indicator of the USB location varies depending on the number of
installed USBs.
Confirm the location of replaced USB depending on the following table.
[USB is not installed in the USB port on the front panel of the server blade]
USB port Location indicator
port 1 port 2 port 1 port 2
Installed N/A /dev/sda N/A
N/A Installed N/A /dev/sda
Installed Installed /dev/sda /dev/sdb
[USB is installed in the USB port on the front panel of the server blade]
USB port Location indicator
port 1 port 2 port 1 port 2
Installed N/A /dev/sdb N/A
N/A Installed N/A /dev/sdb
Installed Installed /dev/sdb /dev/sdc
Executing CBTP
1. Select TEST RUN, and then press Enter key.
2. Test Run Monitor is displayed. Using Tab key, select EXEC, and then
press Enter Key.
Diagnosing server blade
8-13
Hitachi Compute Blade 500 Series System Service Manual