Loading...
3. Confirm that Power LED and Status LED emit in green on the switch
module.
4. Turn on LID LED for identifying the target module.
See Identify LED (LID) on/off procedure on page 4-7 section.
5. Verify the SFP function. See
How to verify the SFP function on page 5-116
section.
This procedure is not needed for LAN switch module.
6. Set up TOD if you need.
See Time of Day (TOD) clock setup procedure on page 4-44 section.
7. If you need to update the firmware, consult with Hitachi Data Systems
Customer Support team.
8. If you are not installing FC switch module, skip this step.
Restore the switch mode of FC switch mode. For detail about the
procedure, see
Restoring switch mode of FC switch module on page 4-27.
9. Restore the configuration data that was backed up.
See Backup/restore procedure on page 4-30 section.
10. If you are not installing 16Gb FC switch module or the monitor mode of
16Gb FC switch module is Fabric, skip this step.
Restore the MAPS action settings. For detail about the procedure, see
Restoring MAPS action settings of 16Gb FC switch module on page 4-30.
11. Verify that the replacement was successful through the MAR log.
See
Alert information identification procedure on page 4-5 section.
12. Turn off the maintenance mode from web console.
See Maintenance mode on/off procedure on page 4-10 section.
13. Turn off LID LED for identifying the target module.
See
Identify LED (LID) on/off procedure on page 4-7 section.
Replacing a LAN pass through module, LAN pass through
module2
This procedure describes how to replace a LAN pass through module, LAN
pass through module2.
Removing a LAN pass through module, LAN pass through module2
Notice:
Be sure that the redirected network is active or the critical network has
stopped to avoid important data loss before removing the switch module.
1. Put on an anti-static wrist strap.
2. Connect web console. See Web console login procedure on page 4-3
section.
5-112