24. Turn off LID LED for identifying the target blade.
See Identify LED (LID) on/off procedure on page 4-7 section.
Notice:
Do not install the server blade without the top cover. The server chassis
has a mechanical security to prevent installation without the top cover.
Bypassing this security feature can cause serious server chassis or server
blade damage.
Removing a PCI expansion blade from server chassis
1. Put on an anti-static wrist strap.
2. Connect web console. See Web console login procedure on page 4-3
section.
3. Power off the target server blade. See Power down procedure on page
4-58 section.
4. Turn on LID LED for identifying the target blade. See Identify LED (LID)
on/off procedure on page 4-7 section.
5. Turn on the maintenance mode from web console. See Maintenance mode
on/off procedure on page 4-10 section.
6. Identify F/W version and take notes of it. See F/W version identification
procedure on page 4-22 section.
7. Release the blue lock tab and pull the lever, as shown below.
8. Holding the server blade, carefully slide out from the chassis and place it
on an anti-static mat.
Figure 5-11 Removing the PCI expansion blade
Notice:
Replacing parts
5-15
Hitachi Compute Blade 500 Series System Service Manual