5. Controller Configuration window is displayed. Confirm and record the
configuration of MultiChannel Support and Personality.
6. Select Continue, and then press Enter key.
Note: The Controller number of the replaced CNA or LAN card varies
depending on the server model and the mezzanine card slot#.
Identify the Controller number according to the criteria in the following
table.
Two Controller number are assigned to a CNA or LAN card.
One Controller number is assigned to an onboard LOM.
No. Server model
# of CNA 
1
# of CTRL 
2
Controller #
1 GGAGC0An-
or GGAGB0An-
without LOM
1 2 #0, #1 for the
mezzanine
2 2 3 #0, #1 for Mezz#1
#2, #3 for Mezz#2
3 GGAGC0Bn-
with LOM
0 1
#0 for LOM 
3
1 3
#0 for LOM 
3
#1, #2 for the
mezzanine
4 GGAGD0An-
without LOM
1 2 #0, #1 for the
mezzanine
5 2 4 #0, #1 for first
mezzanine #
#2, #3 for second
mezzanine #
6 3 6 #0, #1 for first
mezzanine #
#2, #3 for second
mezzanine #
#4, #5 for third
mezzanine #
7 4 8 #0, #1 for Mezz #1
#2, #3 for Mezz #2
#4, #5 for Mezz #3
#6, #7 for Mezz #4
8 GGAGD0Bn-
with LOM
0 2
#0, #1 for LOMs 
4
1 4
#0, #1 for LOMs 
4
#2, #3 for the
mezzanine
9 2 6
#0, #1 for LOMs 
4
7-58
Configuring Emulex mezzanine card