Move cursor onto Enable/Disable VLAN ID by using ↑ and ↓, and then
press Enter.
Move cursor onto the Enable or Disable as same setting as the failed
CNA product by using ↑ and ↓, and then press Enter.
Confirm that the The current VLAN ID is line changed to the selected
mode.
(Skip this step when the BIOS setting for the first port is set to Disabled
or DCBX mode is CEE.)
12. Press ESC. The window in step 3 is displayed again.
Move cursor onto Configure Advanced Adapter Parameters by using ↑
and ↓, and then press Enter.
13. Move cursor onto Change Default ALPA of this Adapter by using ↑ and
↓, and then press Enter.
Select as same setting as the failed CNA product by using ↑ and ↓ in the
Change Adapter ALPA (HEX) To: line, and then press Enter.
Confirm that The Adapter ALPA is line changed to the selected
hexadecimal.
14. Repeat the above instruction in step 13 by moving cursor onto Change
PLOGI Retry Timer, Enable or Disable Spinup Delay, Auto Scan
Setting, Enable or Disable EDD 3.0, Enable or Disable Start Unit
Command, Enable or Disable Environment Variable, and Enable or
Disable Auto Boot Sector, respectively, and then set as same settings
as the ones of failed CNA product.