Table 2-158 CLI console command
Item Command
Displaying management module firmware show mgmt-module firmware
Updating management module firmware update mgmt-module firmware
Table 2-159 LCD touch console operation
Item Operation
Displaying management module
firmware
Hardware maintenance > Management Module
(MM) > Detail display
Updating management module
firmware
Hardware maintenance > Management Module
(MM) > Firmware update
Tip:
•
When you execute update using HCSM, the management module
firmware version needs to be A0150 or later.
• When executing update using HCSM, see the Hitachi Compute Systems
Manager Software User Guide.
(1) Obtaining the latest versions of Management module firmware/
Dictionary/Equipment parameter
Contact your reseller for where to download the latest management module
firmware, dictionary, and system parameter.
Note:
•
Do not change the file name. If the file name is changed, the
management module cannot recognize it as a firmware file.
• Files for other system units, such as that for CB 2000, cannot be applied.
(2) Checking the current version and management module state:
active or standby
Check that versions of the management module firmware, dictionary, and
equipment parameter, which are obtained in (1), are later than the current
versions.
When a management module firmware is updated, the management module
automatically reboots to disconnect. Check Hot standby status for
management module 0 and 1. Make sure that the active and standby
assignments are the same as those before updating.
1. Click Resources
tab.
2. Click All Modules > Management Modules.