• If you execute update using firmware for another system unit, the update
fails. If so, execute update again using an appropriate file.
•
Do not change the file name. If the file name is changed, the
management module cannot recognize it as a firmware file.
• Files for other system units, such as that for CB 2000, cannot be applied.
(2) Checking the current version
Check that the version of the server blade firmware, which is obtained in (1)
Obtaining the latest version of Server blade firmware on page 2-294, is later
than the current versions.
1. Click Resources
tab.
2. Click Systems > Firmware.
3. The current version is shown as Total version. Check that the latest
version for updating is later than the current version of all target server
blades.
(3) Update
For server blade firmware, updating is processed in background after you
execute updating from the management module console.
1. Store the obtained update file into a place like a hard disk in the system
console.
2. Click Resources
tab.
Functional detail
2-295
Hitachi Compute Blade 500 Series Management Module Setup Guide