EasyManuals Logo

Hitachi Compute Blade 500 Series Management Module Setup Guide

Hitachi Compute Blade 500 Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #346 background imageLoading...
Page #346 background image
HCSM alert log message
Format of alert log messages
[ID]
The message ID
[Level]
The level of the message: Info (information message), WARNING (warning
message), or FAIL (error message)
[Message]
A message is shown."X","Y" in a message stands for characters.
Table A-1 Message list
ID Level Message
Description
FD00 WARNING Temperature of chassis became warning
level.(Temp(X),Location:Y)
[Meaning] The temperature at the part shown in Y is beyond the warning level. X shows
"Upper" or "Lower".
[Action] Although the device can keep running, the high temperature can cause a fault.
Thus, check if something prevents it from cooling down, such as failure in air
conditioners or in fan modules of the unit, and inlet ports covered with dust.
FD01 FAIL Temperature of chassis became error
level.(Temp(X),Location:Y)
[Meaning] The temperature at the part shown in Y is exceedingly high. X shows "Upper"
or "Lower".
[Action] The module with high temperature may stop working to protect hardware.
Consult your reseller or maintenance personnel.
Check if something prevents it from cooling down, such as failure in air conditioners or in
fan modules of the unit, and inlet ports covered with dust.
FD02 Info Temperature of chassis has been
restored to a normal level.
(Temp(X),Location:Y)
[Meaning] The temperature at the part shown in Y is back to the normal level. X shows
"Upper" or "Lower".
[Action] No particular action required.
FD03 WARNING Temperature of CPU became warning
level.(Temp(X),Location:Y)
[Meaning] The temperature of CPU at the part shown in Y is exceedingly high. X shows
"Upper" or "Lower".
[Action] Although the device can keep running, the high temperature can cause a fault
(the message ID: FD04). Thus, check if something prevents it from cooling down, such
as failure in air conditioners or in fan modules of the unit, and inlet ports covered with
dust.
A-2
HCSM alert log message
Hitachi Compute Blade 500 Series Management Module Setup Guide

Table of Contents

Other manuals for Hitachi Compute Blade 500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Compute Blade 500 Series and is the answer not in the manual?

Hitachi Compute Blade 500 Series Specifications

General IconGeneral
BrandHitachi
ModelCompute Blade 500 Series
CategoryServer
LanguageEnglish

Related product manuals