ID Level Message
Description
FD04 FAIL Temperature of CPU became error level.
(Temp(X),Location:Y)
[Meaning] The temperature of CPU at the part shown in Y is beyond the warning level. X
shows "Upper" or "Lower".
[Action] The module with high temperature may stop working to protect hardware.
Consult your reseller or maintenance personnel.
Check if something prevents it from cooling down, such as failure in air conditioners or in
fan modules of the unit, and inlet ports covered with dust.
FD05 Info Temperature of CPU has been restored
to a normal level.(Temp(X),Location:Y)
[Meaning] The temperature of CPU at the part shown in Y is back to the normal level. X
shows "Upper" or "Lower".
[Action] No particular action required.
FD10 WARNING Voltage became warning level.
(Voltage(X),Location:Y)
[Meaning] The voltage at the part shown in Y is beyond the warning level. X shows
"Upper" or "Lower".
[Action] Although the device can keep running, the voltage level can cause a fault (the
message ID: FD11). Consult your reseller or maintenance personnel.
FD11 FAIL Voltage became error level.
(Voltage(X),Location:Y)
[Meaning] The voltage at the part shown in Y is exceedingly high. X shows "Upper" or
"Lower".
[Action] The module with high voltage may stop working to protect hardware. Consult
your reseller or maintenance personnel.
FD12 Info Voltage has been restored to a normal
level.(Voltage(X),Location:Y)
[Meaning] The voltage at the part shown in Y is back to the normal level. X shows
"Upper" or "Lower".
[Action] No particular action required.
FD30 Info Module is installed.(Location:X)
[Meaning] A module at the part shown in X is inserted.
[Action] Nothing is required.
FD31 Info Module is removed.(Location:X)
[Meaning] A module shown at the part in X is removed.
[Action] Nothing is required.
FD38 FAIL Watchdog timer has expired.(Location:X)
[Meaning] Watchdog timeout at the part shown in X is detected.
[Action] Consult your reseller or maintenance personnel.
FD40 WARNING On server, an warning event occurred.
(Location:X,Event:Y)
HCSM alert log message
A-3
Hitachi Compute Blade 500 Series Management Module Setup Guide