2. Maintenance work
A screen for use in the maintenance work by a service personnel is described.
2.1 Setting of maintenance mode by service personnel
For the maintenance work by a service personnel, restrictions on use of the following
functions are removed.
●System environment setup
●Adjustment/operational checkout
●Solenoid valve/pump test
●Download
1Select the maintenance in a menu and then select Password protection.
2Input a password “HALB” and press Limitation change.
[Caution] 1. The password “HALB” is a special password to enable the
predetermined screen related to the control of IJP. Do not tell this
password to the customer.
2. Even when the customer sets the password in the functional
restriction, the “HALB” has priority.
Back
Maintenancemenu
Operation
management
CirculationcontrolLogmanagement
Environmentsetup
menu
Manual
Shut
down
Softwaremanagement
Testprint
Password
protection
Excitationupdate
(Nozzletest)
Status:XXXXX
Afteryouhaveenteredacorrectpassword,youarepermittedto
Password[]
Back
Passwordprotection
Limitation
change
Editmessage/Selectmessage [0](0:access 1:protect)
Savemessage [0](0:access 1:protect)
Printspecifications [0](0:access 1:protect)
changethepasswordprotectionsettingsbelow.
Status:XXXXX
Printformat [0](0:access1:protect)
Maintenance [0](0:access 1:protect)