2.3 Adjustment/operational checkout
2.3.1 Excitation adjustment
●Adjust the drive conditions of nozzles.
●This adjustment is performed in a state other than the IJ printer “ready” state.
●Be sure to perform this adjustment in the case of replacing the board (EZJ93, 94/106,
102), the nozzle (including the print head) or changing the ink type.
In addition, when this adjustment is performed, be sure to carry out “2.3.4 Auto
phase gain adjustment.”
1Press Adjustment/operational checkout at the second page of the
service maintenance screen.
When the Next menu are not displayed in the maintenance work menu, set to
the service personnel maintenance mode by the password protection.
With respect to the
Password protection,
refer to "2.1 setting of
service personnel
maintenance mode".
Solenoidvalve/
pumptest
Adjustment/
operationalcheckout
LanguagechangeUnitinformation
Systemreset
System
environmentsetup
Download
Next
menu
Back
Maintenancemenu
Manual
Shut
down
Status:XXXXX
Back
Adjust./oper.checkout
Chargevoltage
confirmation
Heatingunit
confirmation
Levelsensor
confirmation
Excitation
adjustment
Manual
Shut
down
Phasemargintest
Auto-phasegain
adjustment
Status:XXXXX
Back
Excitationadjustment
Excitationvoltagevalue[740](0〜1023)
Automatic
adjustment
Status:XXXXX
Excitationadjustment
Excitationvoltagevalue[740](0〜1023)
Proc.status:Inprogress
Status:XXXXX