Specifications and Panel Wiring
6 Specifications and Panel Wiring
Specifications
Specification Parameters
Relay Contacts Four Form-C SPDT relays, 3A @ 28VDC (external PTC preferred)
Voltage: 12VDC nominal
Power
Current: 300mA combined with two readers
LED Output Open collector driver capable of sinking up to 8mA
Tamper Supervised or non-supervised input
Data Input TTL compatible inputs
Buzzer Output Open collector driver capable of sinking 8mA at 12VDC
Reader Interface
Reader Type
Honeywell JT-MCR MIFARE Smart READERS
Honeywell HON-MSR MIFARE SECTOR READERS
HONEYWELL OmniProx PROXIMITY READERS
Honeywell OmniClass SMART READERS
Honeywell HON-FIN3000 Fingerprint
Reader 150mA (any of the two reader outputs)
Battery
150mA (battery charge current for the battery wired in
series)
Maximum Output Loading
Total 300mA (combined current of the two reader outputs)
Common Connections
The common connections of supervised input are all connected internally. They are
not connected to the panel chassis.
The common connections of relay output are NOT all connected internally, which are
NOT connected to the panel chassis.
Height: 340mm (13.4inches)
Width: 290mm (11.4inches)
Enclosure Dimension
Depth: 78mm (3.1inches)
Mechanical
Enclosure Weight 5Kg (11lbs), with one battery
Operating: 0˚C ~ 50˚C
Temperature
Storage: -55˚C ~ +85˚C
Environment
Humidity 5% ~ 85% RHNC
Ethernet
Shield, cat5 to RJ-45
(Maximum 10 panels)
330inches (100m)
(Maximum Distance)
Readers 7-Conductor, Shielded
500 inches (153 m)
(Maximum Distance)
Supervisor Input Twisted Pair, Shielded
2,000 inches (610 m)
(Maximum Distance)
Cable
Relay Outputs Twisted Pair, Shielded
2,000 inches (610 m)
(Maximum Distance)
48