EasyManuals Logo

Honeywell XENON 1902 User Manual

Honeywell XENON 1902
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #192 background imageLoading...
Page #192 background image
172 Xenon/Granit User Guide
Send all characters up to a particular character
F3 Include in the output message all characters from the input message, starting with
the character at the current cursor position and continuing to, but not including, the
search character “ss,” followed by an insert character. The cursor is moved forward
to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex
value for its ASCII code, and xx stands for the insert character’s hex value for its
ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page 342 for
decimal, hex and character codes.
F3 Example: Send all characters up to a particular character
Using the bar code above, send all characters up to but not including “D,” followed
by a carriage return.
Command string: F3440D
F3 is the “Send all characters up to a particular character” command
44 is the hex value for a 'D”
0D is the hex value for a CR
The data is output as:
1234567890ABC
<CR>
Send all characters up to a string
B9 Include in the output message all characters from the input message, starting with
the character at the current cursor position and continuing to, but not including, the
search string “s...s.” The cursor is moved forward to the beginning of the “s...s”
string. Syntax = B9nnnns...s where nnnn stands for the length of the string, and s...s
stands for the string to be matched. The string is made up of hex values for the
characters in the string. Refer to the ASCII Conversion Chart (Code Page 1252),
beginning on page 342 for decimal, hex and character codes.
B9 Example: Send all characters up to a defined string
Using the bar code above, send all characters up to but not including “AB.”
Command string: B900024142
B9 is the “Send all characters up to a string” command
0002 is the length of the string (2 characters)
41 is the hex value for A

Table of Contents

Other manuals for Honeywell XENON 1902

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1902 and is the answer not in the manual?

Honeywell XENON 1902 Specifications

General IconGeneral
Operating frequency2400 - 2500 MHz
Standard interfacesBluetooth
Connectivity technologyWireless
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supported-
Battery life14 h
Charging time4.5 h
Input voltage5 V
Battery capacity1800 mAh
Power source typeBattery
Number of reads per charge50000
Power consumption (standby)0.5 W
ShockproofYes
CertificationCE, UL
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight214 g
Base weight179 g
Base dimensions132 x 102 x 81 mm

Related product manuals