Xenon/Granit User Guide 309
Granit 1910i Industrial Corded Scanner Product
Specifications
Motion Tolerance: Up to 240 inches per second for 13 mil UPC
Symbol Contrast Grade 1.0 (20% or greater)
Parameter (Continued) Specification
Parameter Specification
Mechanical
Height 7.7 in. (195.6mm)
Length 5.2 in. (132.1mm)
Width 2.9 in. (73.7mm)
Weight 10.6 oz. (300g)
Electrical
Voltage Requirements 4 - 5.5 VDC at input connector
Current Draw @5VDC ScanningStandby
470mA, 2.35W100mA, 5W
Power Supply Noise Rejection Maximum 100mV peak to peak, 10 to 100 kHz
Illumination LED:
Peak Wavelength 624nm +
18nm (red LED)
IEC 62471: “Exempt Risk Group”
Aiming:
Peak Wavelength Laser 650nm
IEC 60825-1: “Class 2”
Optical Power Laser <1mW
Environmental
Temperature Ranges:
Operating -22F to +122F (-30C to 50C)
Storage -40F to +158F (-40C to 70C)
Humidity 0 to 95% non-condensing
Mechanical Drop Operational after 50 drops from 6.5 feet
(1.98m) to concrete at 23°, -30°, and 50°C
Vibration Complies with MIL-STD-810G, Method 514.6, Annex
C
ESD Tolerance Up to 20kV direct air
Up to 8 kV indirect coupling plane
Sealant Rating IP65
Image
Image Size 838 x 640 pixels