58 Xenon/Granit User Guide
Open Link Mode - Single Scanner
When newly shipped or defaulted to factory settings, a scanner is not linked to a
base or an Access Point. A link is established when the scanner is placed into a
base, or an Access Point linking bar code is scanned. When in Open Link Mode, a
new link is established when a new scanner is placed in the base, or you scan an
Access Point linking bar code. Each time a scanner is placed into a base or scans
an Access Point linking bar code, the scanner becomes linked to the base or Access
point and the old scanner is unlinked.
Unlink the Scanner
If a base or an Access Point has a scanner linked to it, that scanner must be
unlinked before a new scanner can be linked. Once the previous scanner is
unlinked, it will no longer communicate with the base or Access Point. To unlink the
scanner from a base or an Access Point, scan the Unlink Scanner bar code below.
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base or an Access
Point, scan the Override Locked Scanner bar code below with a new scanner and
place that scanner in the base, or scan the Access Point linking bar code. The
locked link will be overridden; the broken or lost scanner’s link with the base or
Access Point will be removed, and the new scanner will be linked.
Out-of-Range Alarm
If your scanner is out range of the base, an alarm sounds from both your base and
scanner. If your scanner is out range of an Access Point, an alarm sounds from just
the scanner. The alarm stops when the scanner is moved closer to the base or
Access Point, when the base or Access Point connects to another scanner, or when
the alarm duration expires. To activate the alarm options for the scanner or the
* Open Link Mode
(Single Scanner)
Unlink Scanner
Override Locked Scanner
(Single Scanner)

Table of Contents

Other manuals for Honeywell XENON 1902

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1902 and is the answer not in the manual?

Honeywell XENON 1902 Specifications

General IconGeneral
Operating frequency2400 - 2500 MHz
Standard interfacesBluetooth
Connectivity technologyWireless
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supported-
Battery life14 h
Charging time4.5 h
Input voltage5 V
Battery capacity1800 mAh
Power source typeBattery
Number of reads per charge50000
Power consumption (standby)0.5 W
ShockproofYes
CertificationCE, UL
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight214 g
Base weight179 g
Base dimensions132 x 102 x 81 mm