192 Xenon/Granit User Guide
When Check Character is set to Validate and Transmit, the scanner only reads
Code 39 bar codes printed with a check character, and will transmit this character
at the end of the scanned data. Default = No Check Character.
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 188) for additional information. Minimum and Maximum
lengths = 0-48. Minimum Default = 0, Maximum Default = 48.
Code 39 Append
This function allows the scanner to append the data from several Code 39 bar
codes together before transmitting them to the host computer. When the scanner
encounters a Code 39 bar code with the append trigger character(s), it buffers
Code 39 bar codes until it reads a Code 39 bar code that does not have the append
trigger. The data is then transmitted in the order in which the bar codes were read
(FIFO). Default = Off.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Minimum Message Length
Maximum Message Length
On
* Off