EasyManuals Logo

Honeywell XENON 1902 User Manual

Honeywell XENON 1902
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #289 background imageLoading...
Page #289 background image
Xenon/Granit User Guide 269
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the sub-
set of commands available that match the Tag field. In this case, the Data field
should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the spe-
cific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence. Only the
Tag, SubTag, and Data fields must be repeated for each command in the sequence.
If additional commands are to be applied to the same Tag, then the new command
sequence is separated with a comma (,) and only the SubTag and Data fields of the
additional command are issued. If the additional command requires a different Tag
field, the command is separated from previous commands by a semicolon (;).
Responses
The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of
the allowable range for this Tag and SubTag combination, e.g., an
entry for a minimum message length of 100 when the field will only
accept 2 characters.
When responding, the device echoes back the command sequence with the status
character inserted directly before each of the punctuation marks (the period, excla-
mation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example: What is the range of possible values for Codabar Coding Enable?
Enter: cbrena*.
Response: CBRENA0-1[ACK]

Table of Contents

Other manuals for Honeywell XENON 1902

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1902 and is the answer not in the manual?

Honeywell XENON 1902 Specifications

General IconGeneral
Operating frequency2400 - 2500 MHz
Standard interfacesBluetooth
Connectivity technologyWireless
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supported-
Battery life14 h
Charging time4.5 h
Input voltage5 V
Battery capacity1800 mAh
Power source typeBattery
Number of reads per charge50000
Power consumption (standby)0.5 W
ShockproofYes
CertificationCE, UL
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight214 g
Base weight179 g
Base dimensions132 x 102 x 81 mm