Page #110 background imageLoading...
Page #110 background image
Target: iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538
Alias: -
Bi-directional Authentication: disabled
Authentication Type: NONE
Login Parameters (Default/Configured):
Data Sequence In Order: yes/-
Data PDU In Order: yes/-
Default Time To Retain: 20/-
Default Time To Wait: 2/-
Error Recovery Level: 0/-
First Burst Length: 65536/-
Immediate Data: yes/-
Initial Ready To Transfer (R2T): yes/-
Max Burst Length: 262144/-
Max Outstanding R2T: 1/-
Max Receive Data Segment Length: 8192/65536
Max Connections: 1/-
Header Digest: NONE/-
Data Digest: NONE/-
Configured Sessions: 1
Monitor Multipath devices
Once virtual disks are presented by HP P6000 Command View to the Solaris host, the following
commands should be used to monitor the configuration:
1. iscsiadm list target -S
This command lists targets with their presented LUNs. In a multipath environment, the same
LUN number should appear under different EVA port targets from the same controller.
Example:
iscsiadm list target -S
Target: iqn.2004-09.com.hp.fcgw.mez50.2.01.50014380025da539
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor: HP
Product: HSV340
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Target: iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor: HP
Product: HSV340
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
2. mpathadm list lu
This command lists the total and operational path count for each logical unit. Both controller
and device path counts are displayed.
Example:
#mpathadm list lu
/scsi_vhci/array-controller@g50014380025c4170
Total Path Count: 2
Operational Path Count: 2
/dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Total Path Count: 2
110 iSCSI or iSCSI/FCoE configuration rules and guidelines

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers