becomes an ordinary virtual disk, you may present that virtual disk as you would any other
ordinary virtual disk.
• HBA must be properly configured to work in a single HBA server configuration. The user is
required to:
◦ Download and extract the contents of the TAR file.
HBA configuration
• Host 1 is a single path HBA host.
• Host 2 is a multiple HBA host with multipathing software.
See Figure 65 (page 139).
Risks
• Single path failure may result in loss of data accessibility and loss of host data that has not
been written to storage.
• Controller shutdown results in loss of data accessibility and loss of host data that has not been
written to storage.
NOTE: For additional risks, see “Oracle Solaris” (page 148).
Limitations
• HP P6000 Continuous Access is not supported with single path configurations.
• Single path HBA server is not part of a cluster.
• Booting from the SAN is not supported.
Figure 65 Oracle Solaris configuration
5. SAN switch 11. Network interconnection
6. SAN switch 22. Single HBA server (Host 1)
7. Controller A3. Dual HBA server (Host 2)
8. Controller B4. Management server
Oracle Solaris configuration 139