Table 31 iSCSI or iSCSI/FCoE module log messages (continued)
FC controller reported a fatal error while processing
an Execute IOCB command.
ErrorFC#%d: QLVerifyMenloFw:
EXECUTE_COMMAND_IOCB fatal
error
108050
FC controller reported failure status for a Get
Firmware State command.
ErrorFC#%d: QLGetFwState: Get
Firmware State failed 0-3
%x %x %x %x
108064
Request to reset the FC processor (adapter) received
from IOCTL interface.
InfoFC#%d: QLIoctlDisable: Reset
adapter
118882
FC loop initialization process (LIP) occurred. The LIP
type is reported, as is the contents of the FC
processor’s mailbox 1 register.
InfoFC#%d: QLIsrEventHandler: LIP
occurred (%x): mailbox1 =
%x
119088
FC LIP reset occurred. The LIP reset type is reported,
as is the contents of the FC processor’s mailbox 1
register.
InfoFC#%d: QLIsrEventHandler: LIP
reset occurred (%x):
mailbox1 = %x
119089
FC link up occurred. Event status is reported, as is
the contents of the FC processor’s mailbox 1
register.
InfoFC#%d: QLIsrEventHandler: Link
up (%x) mailbox1 = %x
119090
FC link up occurred. Event status is reported, as is
the RunTimeMode (0 = loop, 1 = point-to-point).
InfoFC#%d: QLIsrEventHandler: Link
mode up (%x): RunTimeMode=%x
119092
An RSCN was received. Event status is reported,
as is the RSCN information.
InfoFC#%d: QLIsrEventHandler: RSCN
update (%x) rscnInfo: %x
119093
FC port update. Event status is reported, as is the
contents of the FC processor’s mailbox 1, 2, and 3
registers.
InfoFC#%d: QLIsrEventHandler: Port
update (%x) mb1-3 %x %x %x
119097
RPC (remote procedure call) server initialization
entry point.
ErrorUserQBRPC_Initialize: Entered139265
Get System API memory allocation failed.ErrorUserQBRPC_Initialize:GetBridge
Mem Allocation error
139266
Get System Advanced API memory allocation failed.ErrorUserQBRPC_Initialize:GetBridgeAdv
Mem Allocation error
139267
Get Management API memory allocation failed.ErrorUserQBRPC_Initialize:GetMgmt Mem
Allocation error
139268
Get iSCSI API memory allocation failed.ErrorUserQBRPC_Initialize:GetIscsi
Mem Allocation error
139269
Get iSCSI advanced API memory allocation failed.ErrorUserQBRPC_Initialize:GetIscsiAdv
Mem Allocation error
139270
Get iSNS API memory allocation failed.ErrorUserQBRPC_Initialize:GetIsns Mem
Allocation error
139271
Get FC Interface API memory allocation failed.ErrorUserQBRPC_Initialize:GetFcIntfc
Mem Allocation error
139272
Get FC Advanced API memory allocation failed.ErrorUserQBRPC_Initialize:GetFcAdv
Mem Allocation error
139273
Failed memory allocation for Get FC SFP API.ErrorUserQBRPC_Initialize:GetFcSfp
Mem Allocation error
139280
Failed memory allocation for Get Log API.ErrorUserQBRPC_Initialize:GetLog Mem
Allocation error
139281
Failed memory allocation for Get Statistics API.ErrorUserQBRPC_Initialize:GetStats
Mem Allocation error
139282
276 iSCSI and iSCSI/FCoE module log messages

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers