EasyManuals Logo

HP EVA P6000 User Manual

HP EVA P6000
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #212 background imageLoading...
Page #212 background image
Reply from 10.6.0.194: bytes=56 time=0.1ms
Reply from 10.6.0.194: bytes=56 time=0.1ms
Reply from 10.6.0.194: bytes=56 time=0.1ms
Reply from 10.6.0.194: bytes=56 time=0.1ms
Reply from 10.6.0.194: bytes=56 time=0.1ms
Ping Statistics for 10.6.0.194:
Packets: Sent = 8, Received = 8, Lost = 0
Approximate round trip times in milli-seconds:
Minimum = 0.1ms, Maximum = 1.3ms, Average = 0.2ms
Quit
Exits the command line interface and returns you to the login prompt (same as the exit command).
NoneAuthority
quitSyntax
Example 1:The following example shows the quit command for the iSCSI or iSCSI/FCoE module:
MEZ50 <1>(admin) #> quit
MEZ50 login:
Reboot
Restarts the module firmware.
Admin sessionAuthority
rebootSyntax
Example:
MEZ50 <1>(admin) #> reboot
Are you sure you want to reboot the System (y/n): y
System will now be rebooted...
Reset
Restores the module configuration parameters to the factory default values. The reset factory
command deletes all LUN mappings, as well as all persistent data regarding targets, LUNs, initiators,
virtual port group settings, log files, iSCSI and MGMT IP addresses, FC and Ethernet port statistics,
and passwords. This command also restores the factory default IP addresses. The reset mappings
command clears only the LUN mappings.
Admin sessionAuthority
factory
mappings
resetSyntax
factoryKeywords
mappings
Example 1:
MEZ50 <1>(admin) #> reset factory
Are you sure you want to restore to factory default settings (y/n): y
Please reboot the System for the settings to take affect
Example 2:
MEZ50 <1>(admin) #> reset mappings
Are you sure you want to reset the mappings in the system (y/n): y
Please reboot the System for the settings to take affect.
212 Command reference

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers

Related product manuals