2. Enable CHAP for the Microsoft iSCSI Initiator:
a. Click Discovery.
• For manually discovering iSCSI target portals:
a. Click Add under Target Portals.
b. Enter the IP address of the iSCSI port of the iSCSI or iSCSI/FCoE module.
c. Click Advanced.
d. Select the CHAP Login Information check box.
e. Enter the CHAP secret for the iSCSI or iSCSI/FCoE modules discovered iSCSI
Initiator in the Target Secret box. For example:
CHAPsecret01
f. Click OK and the initiator completes Target discovery.
• Using iSNS for target discovery:
a. Click Add under iSNS Servers.
b. Enter the IP address of the iSNS server.
c. Click OK.
b. Click Targets.
c. Select the appropriate target for login.
d. Click Log On.
e. Click Advanced.
f. Select the CHAP Login Information check box.
g. Enter the CHAP secret for the iSCSI or iSCSI/FCoE modules discovered iSCSI Initiator in
the Target Secret box.
h. Click OK.
i. Click OK and the initiator completes normal login.
Enabling CHAP for the iSCSI or iSCSI/FCoE module-discovered iSCSI initiator entry
CHAP can be enabled via CLI only. To enable CHAP for the iSCSI or iSCSI/FCoE modules
discovered iSCSI Initiator entry using the iSCSI or iSCSI/FCoE module's CLI:
1. If the iSCSI Initiator is not listed under set chap command:
a. HP Command View Option: add the initiator iqn name string via HP Command View’s
Add Host tab.
• Go to HP Command View and select Hosts then select the Add Host tab and enter
the iqn name string.
b. CLI Option: Enter the initiator add command and add the iSCSI Initiator that is about to
do discovery.
2. If the iSCSI Initiator is listed under the set chap command, enable CHAP secret. For example:
CHAPsecret01.
a. Select the index of the iSCSI Initiator.
b. To Enable CHAP, select 0, then enter the CHAP secret.
122 iSCSI or iSCSI/FCoE configuration rules and guidelines

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers