3. Enable CHAP for the Microsoft iSCSI Initiator.
a. Click the General tab.
b. Click Secret in the middle of the screen.
c. Click Reset.
d. Enter the iSCSI or iSCSI/FCoE controller iSCSI Presented Target CHAP secret. For example:
hpstorageworks.
e. Click Discovery.
• For manually discovering iSCSI target portals:
a. Click Add under Target Portals.
b. Enter the IP address of the iSCSI port of the iSCSI or iSCSI/FCoE controller.
c. Click Advanced.
d. Select the CHAP Login Information check box.
e. Enter the CHAP secret for the iSCSI or iSCSI/FCoE controller discovered iSCSI
Initiator in the Target Secret box. For example: CHAPsecret01.
f. Click OK and the initiator completes target discovery.
• Using iSNS for target discovery:
a. Click Add under iSNS Servers.
b. Enter the IP address of the iSNS server.
c. Click OK.
f. Click Targets.
g. Select the appropriate target for login.
h. Click Log On.
i. Click Advanced.
j. Select the CHAP Login Information check box.
k. Enter the CHAP secret for the iSCSI or iSCSI/FCoE controller discovered iSCSI Initiator
in the Target Secret box. For example: CHAPsecret01.
l. Select the Mutual Authentication check box.
m. Click OK.
n. Click OK and the initiator completes normal login.
Enabling bi-directional CHAP during discovery and single–direction CHAP during
normal session
Table 20 (page 126) lists the parameters you need to enable bi-direction CHAP during discovery
and bi-directional CHAP during normal session.
Table 20 Parameters enabling bi-direction CHAP
MS Initiator secret settings
hpstorageworksGeneral Tab SecrethpstorageworksiSCSI Port
CHAPsecret0Add Target PortalCHAPsecret01Discovered iSCSI
Initiator
CHAPsecret01Log on to TargetN/AiSCSI Presented
Target
Note: These secret settings are for example only. Please configure CHAP with settings that apply to your specific
network environment.
126 iSCSI or iSCSI/FCoE configuration rules and guidelines

Table of Contents

Other manuals for HP EVA P6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EVA P6000 and is the answer not in the manual?

HP EVA P6000 Specifications

General IconGeneral
ModelHP EVA P6000
Number of Storage Controllers2
Management SoftwareHP Command View EVA
Drive TypesSAS, SSD
RAID LevelsRAID 0, 1, 5, 6
Connectivity8 Gb Fibre Channel, 10 Gb iSCSI, 1 Gb iSCSI
Form FactorRack-mounted
Storage Controller TypeDual controllers

Related product manuals