EasyManuals Logo

HP Integrity rx4640 User's & Service Guide

HP Integrity rx4640
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Chapter 4
Removing and Replacing Components
Removing and Replacing Server Memory DIMMs
46
Replacing the Memory Extender Board
To replace the memory extender board, follow these steps:
Step 1. Ensure the extraction levers are positioned in the outward, unlocked position. Figure 4-7 shows
how to install the memory extender board.
Step 2. Align the memory extender board with the front and rear chassis guide slots.
Step 3. Slide the memory extender board in until it begins to seat in the socket located on the midplane
board.
Step 4. Push the extraction levers inward to the locked position in order to plug in the memory extender
board into the midplane riser board.
Step 5. Replace the front cover. See “Replacing the Front Cover” on page 43.
Step 6. Replace the front bezel. See “Replacing the Front Bezel” on page 41.
Step 7. If rack mounted, slide the HP server into the rack until it stops. See “Inserting the Server into the
Rack” on page 39.
Removing and Replacing Server Memory DIMMs
Use these procedures to remove and replace server memory DIMMs. server memory DIMMs are located on
the memory extender board.
WARNING Ensure that the server is powered down and all power sources have been
disconnected from the server prior to removing or replacing server memory DIMMs.
Voltages are present at various locations within the server whenever an ac power
source is connected. This voltage is present even when the main power switch is in
the off position.
Failure to observe this warning could result in personal injury or damage to
equipment.
CAUTION Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD
safety precautions could result in damage to the server.
Removing Server Memory DIMMs
To remove server memory, follow these steps:
Step 1. If rack mounted, slide the HP server out from the rack until it stops. See “Extending the Server
from the Rack” on page 39.

Table of Contents

Other manuals for HP Integrity rx4640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx4640 and is the answer not in the manual?

HP Integrity rx4640 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx4640
CategoryServer
LanguageEnglish

Related product manuals