Appendix C
Utilities
Extensible Firmware Interface Boot Manager
164
EFI Commands
Table C-1 lists EFI commands for the HP Integrity rx4640 server. The equivalent BCH commands found in
PA-RISC based servers are also listed.
Table C-1 EFI Commands
EFI Shell
Command
BCH
Command
Equivalent
(PA-RISC)
BCH Command Parameters
(PA-RISC)
Definition
These commands are found in all other menus
info boot Boot [PRI|HAA|ALT|<path>] Boot from specified path
help <command> HElp [<menu>|<command>] Display help for specified
command or menu
reset RESET Reset the server (to allow
reconfiguration of
complex
exit (at EFI shell) MAin Return to the main menu
MAin
EFI boot manager
“change boot
order”
PAth [PRI|HAA|ALT|CON|KEY|<path>] Display or modify a path
bcfg SEArch [ALL] Search for boot devices
bcfg SEArch [DIsplay|IPL] [<path>] Search for boot devices
many commands
offer a [-b]
parameter to cause
25 line breaks
ScRoll [ON|OFF] Display or change
scrolling capability
COnfiguration
autoboot AUto [BOot|SEarch|STart] [ON|OFF] Display or set the auto
start flag
info boot BootID [<processor #>[<bootid #>]] Display or set processor
boot identifier
EFI boot manager Boot info Display boot-related
information
autoboot BootTimer [0-200] Seconds allowed for boot
attempt
cpuconfig CPUconfig [<cpu>][ON|OFF]] Config/deconfig processor
boottest FastBoot [ON|OFF] or [test] [RUN|SKIP] Display or set boot tests
execution

Table of Contents

Other manuals for HP Integrity rx4640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx4640 and is the answer not in the manual?

HP Integrity rx4640 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx4640
CategoryServer
LanguageEnglish

Related product manuals